Services What We Inspect Legislation & Deadlines Pricing Contact
+420 603 411 895 Get Quote

Worry-free electrical equipment inspections

We carry out inspections, checks and tests of electrical appliances, electric hand tools, electrical machinery, and all designated low-voltage (LV) technical electrical equipment (VTEZ), which employers arrange to fulfill their occupational health and safety (OHS) obligations in the workplace.

18 years of experience
Thousands of inspected devices

Guaranteed REVELZA Inspection Standard

Complete inspection service for companies and institutions, or their premises, without interrupting normal workplace operations.

Measurements taken with certified, regularly calibrated instruments
Inspection report in PDF format (a printed copy available for an extra fee)
Free electronic record-keeping with tracking of upcoming inspection and check deadlines
Compliance with legal requirements, ČSN standards, and occupational health and safety (OHS) requirements within organizations
Durable QR-coded identification labels on electrical appliances and machinery
SCOPE OF INSPECTION SERVICES

What We Inspect For You

Electrical appliances

Common equipment found in offices, kitchenettes, warehouses, server rooms and technical rooms in administrative buildings, schools, workshops and other premises.

  • Desktop PCs, power supplies for laptops and docking stations, monitors, printers, phone chargers and other adapters, servers, switches, detachable power cords
  • Refrigerators, dishwashers, coffee machines, grinders, blenders, microwave ovens, electric kettles, washing machines
  • Extension cords

Electric tools

Equipment for workshops, production spaces, construction sites and rental facilities (assuming heavier use).

  • Electric hand tools (drills, grinders, saws, nail guns)
  • Bench grinders, saws, milling machines, pillar drills
  • Welding machines
  • ELECTRICAL MACHINERY (ČSN EN 60204-1 ed. 3)
  • Any type of machinery

Designated technical electrical equipment (VTEZ)

Both high-current and low-current building installations, lightning protection and EV charging infrastructure.

  • Building electrical installations with distribution boards
  • Annual inspections of emergency lighting systems as fire-protection equipment
  • Lightning conductors (lightning protection) / LPS
  • Wallboxes and EV charging stations.
Apartment and family houses

Inspections of main building supply lines (HDV), common areas, and electricity meter distribution boards

We provide inspections of the main building supply line (HDV), electrical installations in common areas, and specific building systems (M&C/BMS systems, boiler rooms, HVAC) in apartment and residential buildings, including inspections of electricity meter distribution boards for these buildings and family houses, in accordance with the applicable connection conditions in the territory of the City of Prague (PREdistribuce, a.s. distribution network).

Specialized scope for apartment/residential buildings:

Main building supply line (HDV), riser cables and branch lines to electricity meters
Electrical installations in common areas (corridors, staircases, cellars, garages)
Specific building equipment and M&C/BMS systems (measurement, control, ventilation, boiler rooms)
Electricity meter distribution boards and metering installation preparations (PREdistribuce, a.s.)
Request an inspection

Express inspections within 5 business days

Need an urgent inspection ahead of an OHS audit or building approval? We respond immediately throughout Prague and Central Bohemia.

Urgent Inquiry

Legislation & Operator Obligations

Arranging inspections is not merely a recommendation but a legal obligation of every employer, operator or property owner to ensure safety.

Selected Legislation for Electrical Appliances and Machinery 5 regulations · links to the full text
Selected Legislation for Classified Equipment (VTZ) 2 regulations · links to the full text

Risks of Neglecting Inspections

Operating electrical equipment without a valid inspection report carries serious consequences:

Loss of Insurance Coverage: In the event of a fire or injury caused by defective equipment without a valid inspection, insurers may reduce or completely refuse to pay out claims.
State Inspection Fines: The State Labor Inspection Authority can impose fines up to CZK 2,000,000 during audits for missing compliance records.
Criminal Liability: In case of electric shock leading to injury or fatalities, management faces direct personal criminal prosecution.
STANDARDS & INTERVALS

Inspection Interval Guidelines

The intervals for regular inspections and checks are set by standards according to the nature of operation and the way the equipment is used.

Inspection Interval Guidelines for Electrical Appliances Groups A–E by type of use
Group / Operational Character Inspection Interval Typical Equipment Examples
Group A — Rental Equipment
Appliances rented out to third-party clients or temporary users.
Every 6 months Rental tools, temporary event appliances (or before every rental)
Group B — Construction Sites
Outdoor areas, construction sites, temporary work areas with a high risk of external influences.
Every 3 to 6 months Construction site distribution boards, concrete mixers, heavy hand drills, extension cords permanently placed outdoors.
Group C — Industry & Workshops
Manufacturing halls, workshops, industrial spaces with high mechanical wear.
Every 6 to 12 months Hand tools, lathes, pillar drills, workshop machinery, welding machines.
Group D — Public Premises
Areas open to the general public, schools, hotels, nursing homes, hostels.
Every 12 to 24 months Hotel appliances, kitchen appliances, school appliances.
Group E — Office & Administration
Standard clean indoor workspaces, desks, meeting rooms, non-industrial environments.
Every 12 to 24 months Computers, monitors, printers, chargers, kitchenette equipment, or hand-held appliances – typically extension cords, plug adapters, hair dryers, irons.
Inspection Interval Guidelines for VTEZ By building type and space
By Building Type and Space: Inspection Interval
Premises designated for administrative activities 5 years
Premises designated for manufacturing, education (schools, kindergartens), accommodation (hotels, hostels, campsites and other lodging facilities) and medical purposes 3 years
Electrical equipment in a building that, per its fire safety design, allows the presence of more than 200 persons 2 years
Temporary construction site installations 6 months
Mobile and transportable equipment 1 year
Areas with fire or explosion hazard 3 years
Wet areas and areas with constant presence of corrosive or contaminating substances 1 year
Protection Against Atmospheric and Static Electricity: Inspection Interval
LPS protecting critical systems 2 years
LPS protecting other buildings or equipment 4 years
FAIR & TRANSPARENT

Service Pricing

Prices are final and include no hidden fees. VAT is charged at the statutory rate. We automatically offer an individual discount for larger volumes.

APPLIANCES

STARTER

up to 20 pcs

1,900 CZK
flat rate for the whole package
APPLIANCES

LARGE OPERATIONS

over 100 pcs

Custom pricing
tailored volume discount
MACHINERY

From smaller machines to extensive installations

from CZK 490
per inspected item
VTEZ (DESIGNATED ELECTRICAL EQUIPMENT)

Installations, lightning conductors, etc.

from CZK 2,900
per inspected device

What's always included in the price:

Comprehensive inspection service with no unpleasant hidden fees.

Visual inspection itself, professional measurement, condition assessment
Labeling of every electrical appliance with a QR-coded ID tag
Preparation of a detailed inspection report in digital PDF format
Free electronic record-keeping with automatic tracking of upcoming deadlines
Transportation within Prague.
Request
GET IN TOUCH

Request / Contact Us

Reach out to us today. We will gladly prepare a custom price proposal tailored to the precise size and nature of your electrical assets.

Direct Phone
Available Mon–Fri 8:00 – 17:00
Email Address
Fast quote turnaround within 48h
Registered Office & Region
Vlasty Buriana 490/3, 190 15, Praha 9 – Satalice
Serving Prague, Central Bohemia & Liberec Region
By submitting this form, you acknowledge the for the purpose of handling your inquiry.